POL Scientific / Bladder / Volume 11 / Issue 3 / DOI: 10.14440/bladder.2024.0004
Cite this article
11
Download
17
Citations
209
Views
Journal Browser
Volume | Year
Issue
Search
News and Announcements
View All
RESEARCH ARTICLE

Comparison of two automated urine cytometry systems: Sysmex® UF-1000i and Beckman Coulter® DxU 850 Iris

Abderrazak Saddari1,2,3* Said Ezrari1,3 Mohammed Dalli4 Elmostapha Benaissa5,6 Yassine Ben Lahlou5,6 Mostafa Elouennass5,6 Adil Maleb1,2,3
Show Less
1 Laboratory of Microbiology, Faculty of Medicine and Pharmacy, University Mohammed the First, Oujda, 60000, Morocco
2 Laboratory of Microbiology, Mohammed VI University Hospital, Oujda, 60000, Morocco
3 Laboratory of Bioresources, Biotechnology, Ethnopharmacology and Health, Faculty of Sciences, University Mohammed the First, Oujda, 60000, Morocco
4 Higher Institute of Nursing Professions and Health Techniques, Oujda, 60000, Morocco
5 Department of Bacteriology, Mohammed V Teaching Military Hospital, Rabat, 10045, Morocco
6 Epidemiology and Bacterial Resistance Research Team/BIO-INOVA Centre, Faculty of Medicine and Pharmacy, University Mohammed V, Rabat, 10045, Morocco
Bladder 2024 , 11(3), e21200016; https://doi.org/10.14440/bladder.2024.0004
Submitted: 3 June 2024 | Revised: 15 August 2024 | Accepted: 10 October 2024 | Published: 29 November 2024
© 2024 by the Bladder published by POL Scientific. Licensee POL Scientific, USA. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution 4.0 International License ( https://creativecommons.org/licenses/by/4.0/ )
Abstract

Background: Urinary tract infection, defined as the presence of bacteria or yeast in the urinary tract, is the most common community-acquired infection after respiratory infections. The cytobacteriological examination of urine (CBEU) remains the primary diagnostic test for urinary tract infections and is the most frequently conducted test in microbiology laboratories. Direct examination is a crucial step of CBEU, enabling the assessment of cytology, including leukocytes and red blood cells, as well as the identification of crystals, epithelial cells, and microorganisms when present in significant quantities. This examination also provides preliminary results that can guide clinical decision-making. While the standard method for urine cytology is a microscopic examination, automation offers several advantages, including standardized results with higher repeatability, improved reproducibility, increased sample throughput, and seamless data transfer to laboratory information systems. Objectives: This study aimed to compare the performance of two automated urine cytology systems: Sysmex UF-1000i and the Beckman Coulter DxU 850 Iris. Methods: We described the methodology and technology underlying each system and assessed their analytical performance. The UF-1000i uses flow cytometry for the objective characterization and identification of particles based on forward scattering, fluorescence, and adaptive typing analysis. In contrast, the DxU-850 Iris, a urine microscopy analyzer, employs proprietary digital flow morphology technology alongside automatic particle recognition software to isolate, identify, and characterize digital images of particles. Conclusion: Our comparison showed that both systems performed exceptionally well, delivering results that are comparable, and, in some cases, superior to, those obtained through the reference method of optical microscopy.

Keywords
Urinary tract infection
UF-1000i
Flow cytometry
DxU 850 Iris
Digital flow morphology
Funding
None.
References
  1. Saddari A, Benhamza N, Dalli M, et al. Urinary tract infections older adults at Mohammed VI university hospital of Oujda: Case series. Ann Med Surg (Lond). 2023;85(5):1408-1412. doi: 10.1097/ms9.0000000000000581

 

  1. Maleb A, Sebbar EH, Lahlou YB, et al. Cytologie urinaire: UF-1000i versus examen microscopique, dans des conditions réelles d’exercice d’un laboratoire de microbiologie. IRBM News. 2017;38(5):150-154. doi: 10.1016/j.irbmnw.2017.07.001

 

  1. García-Coca M, Gadea I, Esteban J. Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection. J Microbiol Methods. 2017;137:14-18. doi: 10.1016/j.mimet.2017.03.010

 

  1. Maleb A, Lamrabat S, Rifai S, et al. A flowchart is always useful: application to the interpretation of the cytobacteriological examination of urine. Ann Biol Clin. 2019;77(5): 537-542. doi: 10.1684/abc.2019.1486

 

  1. Twizeyimana E. Automates et uroculture: La cytologie urinaire. Rev Francoph Lab. 2016;482:25-33. doi: 10.1016/S1773-035X(16)30169-1

 

  1. Guillou MLJ. Impact de l’automatisation sur l’organisation d’un laboratoire de bactériologie. Rev Francoph Lab. 2016;482:67-73. doi: 10.1016/S1773-035X(16)30174-5

 

  1. Manoni F, Tinello A, Fornasiero L, et al. Urine particle evaluation: A comparison between the UF-1000i and quantitative microscopy. Clin Chem Lab Med. 2010;48(8):1107-1111. doi: 10.1515/CCLM.2010.233

 

  1. Ledru S, Canonne JP. Comparison of IRIS IQ ELITE and microscopy for urinalysis and evaluation of performance in predicting outcome of urine cultures. Ann Biol Clin. 2008;66(5):555-559. doi: 10.1684/abc.2008.0267

 

  1. UF-1000i Une Nouvelle Génération Analyseur Automatisé de Particules d’Urine. Document Number MKT-10-1079-F 08/2010 1M. Sysmex America, Inc. Available from: https:// www.sysmex.com/US/en/brochures/brochure_uf-1000i_mkt- 10-1079-f.pdf [Last accessed on 2024 Mar 04].

 

  1. Analyseur D’urine Entièrement Automatisé UF-1000i. Mode D’emploi. Japon: De Sysmex Corporation; 2006.

 

  1. DxU 850m IRIS and DxU 840m IRIS. User’s Manual. Reference. C49322AB; 2022. Available from: https://www. beckmancoulter.com/dxuiris [Last accessed on 2024 Mar 20].

 

  1. DxU IRIS Automated Urinalysis Solution. Datasheet. Available from: https://medist-srl.ro/sites/default/files/download/ products/852-2021-9530-ua-dxu-iris-workcell-ds-226976-en-glb-a4.pdf [Last accessed 2024 Oct 15].

 

  1. Maleb A, Sebbar EH, Lahlou YB, et al. Évaluation des performances de l’automate de cytologie urinaire sysmex UF- 1000i. IRBM News. 2017;38(6):194-198. doi: 10.1016/j.irbmnw.2017.09.003

 

  1. Dewulf G, Harrois D, Mazars E, Cattoen C, Canis F. Evaluation of the performances of the iQ(®)200 ELITE automated urine microscopy analyser and comparison with manual microscopy method. Pathol Biol. 2011;59(5):264-268. doi: 10.1016/j.patbio.2009.10.006
Conflict of interest
The authors declare no conflicts of interest.
Share
Back to top
Bladder, Electronic ISSN: 2327-2120 Print ISSN: TBA, Published by POL Scientific